RTD Temperature Transmitter/Monitor


 
Our Price: $455.00


Product Code: CMCP560


Range:
  
Alarm Module

  

Description Technical Specs
 

CMCP500 Transmitter Approval LabelThe CMCP560 RTD Temperature Transmitter is compatible with 100 Ohm Platinum 3 wire RTD's. Available in English scaling, the CMCP560 checks for faults, processes the temperature signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a range of 0 to 250° F (-17.7 to 121° C). Combining transmitters with an existing PLC or DCS system results in a high density, low cost temperature monitoring system.

The Optional Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.

Alarms relays and trip multiply are available with the Monitor version.

CMCP500 Monitor Approval LabelAlarms - The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.

Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure.

Trip Multiply - The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up.
 
Custom Input and Output Configurations Available On Request

Fault Detection:

On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to <2 mA to indicate the fault to the readout system. A green LED on the front of the unit is turned off to provide a local indication of the fault.


Documents Available:


Browse for more products in the same category as this item:

Transmitters (Din Rail)
Temperature
TSI Systems


CMCP305 Quick Access Series BNC Boxes - Indoor Locations $109.00
CMCP240 Proximity Switch $150.00
CMCP4190 NPT Proximity Probe Adapters $65.00
CMCP805 Aluminum Proximity Probe Mounting Bracket - Ordering Page $35.00
CMCP801 Relative Proximity Probe Holder - Ordering Page $290.00
CMCP610-01 Benchtop Proximity Probe Static Calibrator - 4140 Target $590.00
CMCP515 Redundancy Module, 10 Amp @ 24VDC $61.00
CMCP545 Proximity Probe In/ Position Out Transmitter $455.00
CMCP270 Series Accelerometer Mounting Tool Kits $225.00
STI Vibration Monitoring Inc.
1010 East Main Street League City, TX  77573
 About Us
 Become an Affiliate
 Privacy Policy
 Send Us Feedback
 
Company Info | Advertising | Product Index | Category Index | Help | Terms of Use
Copyright © 2012 STI Vibration Monitoring Inc.. All Rights Reserved.
Ecommerce Solutions & Shopping Cart Software powered by Volusion.