|
|
|
|
 |
|
CMCP-540 Proximity Probe In/Displacement Out Transmitter
|
Our Price: $445.00
|
|
|

The CMCP540 Radial Vibration, Proximity Probe Based Displacement Transmitter is available in English or Metric scaling. The CMCP540 is compatible with all 100 and 200 mv/mil Proximity Probe Drivers and provides a 4-20 mA output proportional to the overall Peak to Peak vibration measurement. Each unit checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user selectable range of 5.0, 10.0, 15.0, 20.0 or 25.0 mils (or Metric equivalent of 127, 254, 381, 508, 635 microns). Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. CSA & UL Approved
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-540A Proximity Probe In/ Displacement Out
|
Our Price: $750.00
|
|
|

The CMCP540 Displacement Monitor is compatable with all manufactures Eddy Probe or Proximity Probe Systems with a voltage output of 200 mv/mil and is available in English or Metric scaling. The CMCP540 checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user selected range of 0 to 5, 10, 15, 20 or 25 mils (0 to 127, 254, 381, 508 or 635 microns). Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
The CMCP540A Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
CSA & UL Approved
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-545 Proximity Probe In/ Position Out Transmitter
|
Our Price: $445.00
|
|
|

The CMCP545 Position (Thrust) Transmitter is compatable with all manufactures Eddy Probe or Proximity Probe Systems with a voltage output of 100 or 200 mv/mil and is available in English and Metric scaling. The CMCP545 checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to range of 0 to 80 mils (40-0-40) or the Metric equivalent of 0 to 2 mm (1.0-0-1.0 mm). Internal Jumpers select normal motion towards or away from sensor. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. CSA & UL Approved
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-545A Proximity Probe In/ Position Out Monitor
|
Our Price: $750.00
|
|
|

The CMCP545 Position (Thrust) Monitor is compatable with all manufactures Eddy Probe or Proximity Probe Systems with a voltage output of 100 or 200 mv/mil and is available in English and Metric scaling. The CMCP545 checks for faults, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to range of 0 to 80 mils (40-0-40) or the Metric equivalent of 0 to 2 mm (1.0-0-1.0 mm). Internal Jumpers select normal motion towards or away from sensor. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
The CMCP545A Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
CSA & UL Approved
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-560 Isolated RTD Temperature Transmitter
|
Our Price: $445.00
|
|
|

The CMCP560 RTD Temperature Transmitter is compatable with 100 Ohm Platinum 3 wire RTD's. Available in English scaling, the CMCP560 checks for faults, processes the temperature signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a range of 0 to 250° F (-17.7 to 121° C). Combining transmitters with an existing PLC or DCS system results in a high density, low cost temperature monitoring system. CSA & UL Approved
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-560A Isolated RTD Temperature Monitor
|
Our Price: $750.00
|
|
|

The CMCP560 RTD Temperature Monitor is compatable with 100 Ohm Platinum 3 wire RTD's. Available in English scaling, the CMCP560 checks for faults, processes the temperature signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a range of 0 to 250° F (-17.7 to 121° C). Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
The CMCP560A Alarm Module provides ok, alert and danger relays, selectable time delay, trip multiply, bypass and 0 to 5 VDC outputs for displays. The relay outputs can be used to trigger machine shut-down or other alarms. Combining transmitters with an existing PLC or DCS system results in a high density, low cost temperature monitoring system.
CSA & UL Approved
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-575 Speed Transmitter
|
Our Price: $725.00
|
|
|

The CMCP575 Isolated Speed Three-Wire Transmitter is one in a family of the 500 Series Transmitters that provide field mounted efficiency and ease of wiring in a compact DIN package. The CMCP575 accepts a frequency or pulse rate input and converts it to a standard process signal output, 4-20mA for interfacing directly with PLC's, DCS's and process computers.
The CMCP575 provides independent linearity equivalent to 14-bit digital accuracy and include user friendly features such as wide ranging and non-interactive zero and span controls. The power range is 15 to 42 VDC @ 28 mA typical.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-TACH3 Tachometer
|
|
|

The CMCP-TACH3 is front panel programmable for single or multiple pulses per revolution and scaling. It may be used as Tachometer, Rate-meter, Counter, or a Totalizer. The tachometer also offers Rate Of Acceleration. The CMCP-TACH3 offers a fixed or floating decimal point and can be supplied with Remote Optical, Infrared, Laser, Proximity, and Magnetic Sensors. It is directly compatible with a TTL input and a 200mV to 50 Vac signal. The TACH3 has front panel programmable set points, analog voltage and current, TTL and RS232 outputs. The TACH3 can be modified to accept a -24 Vdc Eddy Current Probe input. The TACH3 offers more standard features than any other tachometer available.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-LVDT-51A 2" LVDT With 1-6 VDC Output - 2.5mV/mil, +24 VDC
|
Our Price: $1,650.00
|
|
|

In Turbine Supervisory Instrumentation (TSI), case expansion is an important measurement. Case expansion (or shell expansion) is the growth of the machine case with increase of temperature during machine startup and on-line operations. The LVDT is mounted to the foundation at the opposite end from where the turbine casing is attached. The LVDT provides information on the change of position of the point measured relative to the foundation.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-VALVE Rotary Valve Position Potentiometer
|
Our Price: $900.00
|
|
|

The working component of the CMCP-VALVE valve position transmitter is a precision long-life rotary potentiometer. Attached to the end of the steam valve control shaft on a large steam turbine, the Valve Position Transducer provides a voltage proportional to the valve’s position. The Valve Position Transducer is directly compatible with the CMCP-549 Valve Position Transmitter, which provides excitation voltage and outputs a 4-20 mA analog signal proportionate to the percentage of valve opening.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-547 Differential Expansion Transmitter
|
Our Price: $660.00
|
|
|

The CMCP547 Differential Expansion Monitors are compatible with LVDT and proximity probe inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-2 inches. Combining monitors with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. With the alarm feature, the unit functions as a complete single channel monitor that includes alert and danger alarms, and output relays.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-547A Differential Expansion Monitor
|
Our Price: $920.00
|
|
|

The CMCP547 Differential Expansion Monitors are compatible with LVDT and proximity probe inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-2 inches. Combining monitors with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. With the alarm feature, the unit functions as a complete single channel monitor that includes alert and danger alarms, and output relays.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-548 Case Expansion Transmitter for LVDT's
|
Our Price: $660.00
|
|
|

The CMCP548 Case Expansion transmitters are compatible with 10mV/mil LVDT inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-2.0 inches. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-548A Case Expansion Monitor for LVDT's
|
Our Price: $920.00
|
|
|

The CMCP548A Case Expansion monitors are compatible with 10mV/mil LVDT inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-2 inches. Combining monitors with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.
|
|
 |
 |
 |
 |
|
|
|
|
 |
|
CMCP-549 Valve Position Transmitter
|
Our Price: $660.00
|
|
|

The CMCP549 Valve Position transmitters are compatible with rotary potentiometer (resistance) inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the signal, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-100%.
|
|
 |
 |
 |
 |